Data from an Excel spreadsheet prepared by Chris Hohl and emailed 18 March 2015, citing DeGolyer, Volume 32, pp. 94+. Works numbers were 33335-33337, 33373-33375 in April 1909.
The St Louis-Southwestern ordered these Atlantics with slide valves and Stephenson gear,Westcott (Model Railroading Cyclopedia Vol 1, 1960) comments that this small class "broke rules because they were built as late as 1909 with narrow fireboxes, small drivers, and slide valves -- all rare features as Atlantics go." Drury (1993) provides insight when he notes "they were not so much Atlantics as they were Americans with trailing axles."
They were later refitted with 12" (305 mm) diameter piston valves, superheaters, and Walschaerts outside valve gear; see Locobase 16016.
Data from StL&SW 1 - 1932 Folio 725 Locomotive Diagrams supplied in May 2005 by Allen Stanley from his extensive Rail Data Exchange.
Delivered by Baldwin in 1909 with saturated boilers, the class was later updated with superheaters, outside radial valve gear, and 12" (305 mm) piston valves. An increase in cylinder volume preserved the tractive effort as boiler pressure dropped by 15 psi. By then, their firebox heating surface areas included 16 sq ft (1.5 sq m) of arch tubes. Compared to other American 4-4-2s submitted to superheating, these engines had a relatively high percentage of superheater area. All were converted to oil burning.
While two of the sextet -- 600 and 603 -- were scrapped in September 1934 and January 1933, respectively, the other four served well into the 1940s, past the end of World War II, before being scrapped in November 1948 (602), July and August 1949 (605, 604), and February 1952 (601).
Principal Dimensions by Steve Llanso of Middle Run Media | ||
---|---|---|
Class | E1 | E1 - superheated |
Locobase ID | 3483 | 16016 |
Railroad | St Louis Southwestern (Cotton Belt) | St Louis Southwestern (Cotton Belt) |
Country | USA | USA |
Whyte | 4-4-2 | 4-4-2 |
Number in Class | 6 | 6 |
Road Numbers | 600-605 | 600-605 |
Gauge | Std | Std |
Number Built | 6 | |
Builder | Baldwin | Cotton Belt |
Year | 1909 | 1909 |
Valve Gear | Stephenson | Walschaert |
Locomotive Length and Weight | ||
Driver Wheelbase (ft / m) | 6.25 / 1.90 | 6.25 / 1.90 |
Engine Wheelbase (ft / m) | 26.08 / 7.95 | 26.09 / 7.95 |
Ratio of driving wheelbase to overall engine wheelbase | 0.24 | 0.24 |
Overall Wheelbase (engine & tender) (ft / m) | 58.60 / 17.86 | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 52,900 / 23,995 | |
Weight on Drivers (lbs / kg) | 90,000 / 40,823 | 105,800 / 47,990 |
Engine Weight (lbs / kg) | 168,000 / 76,204 | 195,000 / 88,451 |
Tender Loaded Weight (lbs / kg) | 120,000 / 54,431 | 169,600 / 76,929 |
Total Engine and Tender Weight (lbs / kg) | 288,000 / 130,635 | 364,600 / 165,380 |
Tender Water Capacity (gals / ML) | 6000 / 22.73 | 7000 / 26.52 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 12 / 11 | 3500 / 13,248 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 75 / 37.50 | 88 / 44 |
Geometry Relating to Tractive Effort | ||
Driver Diameter (in / mm) | 70 / 1778 | 70 / 1778 |
Boiler Pressure (psi / kPa) | 200 / 1380 | 185 / 1280 |
High Pressure Cylinders (dia x stroke) (in / mm) | 20" x 26" / 508x660 | 21" x 26" / 533x660 |
Tractive Effort (lbs / kg) | 25,257 / 11456.40 | 25,758 / 11683.65 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.56 | 4.11 |
Heating Ability | ||
Tubes (number - dia) (in / mm) | 292 - 2" / 51 | 172 - 2" / 51 |
Flues (number - dia) (in / mm) | 26 - 5.375" / 137 | |
Flue/Tube length (ft / m) | 15 / 4.57 | 14.92 / 4.55 |
Firebox Area (sq ft / m2) | 200 / 18.58 | 216 / 20.07 |
Grate Area (sq ft / m2) | 30.30 / 2.81 | 31.20 / 2.90 |
Evaporative Heating Surface (sq ft / m2) | 2481 / 230.49 | 2109 / 196 |
Superheating Surface (sq ft / m2) | 496 / 46.10 | |
Combined Heating Surface (sq ft / m2) | 2481 / 230.49 | 2605 / 242.10 |
Evaporative Heating Surface/Cylinder Volume | 262.54 | 202.40 |
Computations Relating to Power Output (More Information) | ||
Robert LeMassena's Power Computation | 6060 | 5772 |
Same as above plus superheater percentage | 6060 | 6869 |
Same as above but substitute firebox area for grate area | 40,000 | 47,552 |
Power L1 | 8595 | 15,852 |
Power MT | 421.08 | 660.64 |