Data from Baldwin Negative 4978 as digitized by the DeGolyer Library of Southern Methodist University and archived at [],320. Works number was 41296 in April 1914.
When the ALC had extracted more than 20 years of service out of this typical Baldwin logging Ten-wheeler, it sold it to the Reader Railroad of Reader, Arkansas. The Reader later sold the engine to Meriwether Gravel Company.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 17 |
Locobase ID | 14054 |
Railroad | Arkansas Lumber Company |
Country | USA |
Whyte | 4-6-0 |
Number in Class | 1 |
Road Numbers | 17 |
Gauge | Std |
Number Built | 1 |
Builder | Baldwin |
Year | 1914 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 11.75 / 3.58 |
Engine Wheelbase (ft / m) | 22.17 / 6.76 |
Ratio of driving wheelbase to overall engine wheelbase | 0.53 |
Overall Wheelbase (engine & tender) (ft / m) | 48.92 / 14.91 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 93,200 / 42,275 |
Engine Weight (lbs / kg) | 123,000 / 55,792 |
Tender Loaded Weight (lbs / kg) | 92,000 / 41,731 |
Total Engine and Tender Weight (lbs / kg) | 215,000 / 97,523 |
Tender Water Capacity (gals / ML) | 4500 / 17.05 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 7 / 6 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 52 / 26 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 54 / 1372 |
Boiler Pressure (psi / kPa) | 200 / 1380 |
High Pressure Cylinders (dia x stroke) (in / mm) | 17" x 24" / 432x610 |
Tractive Effort (lbs / kg) | 21,836 / 9904.65 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.27 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 246 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 13.25 / 4.04 |
Firebox Area (sq ft / m2) | 147 / 13.66 |
Grate Area (sq ft / m2) | 23.50 / 2.18 |
Evaporative Heating Surface (sq ft / m2) | 1843 / 171.22 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1843 / 171.22 |
Evaporative Heating Surface/Cylinder Volume | 292.08 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 4700 |
Same as above plus superheater percentage | 4700 |
Same as above but substitute firebox area for grate area | 29,400 |
Power L1 | 7354 |
Power MT | 521.87 |