Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 30, p. 154. Works number was 29574 in November 1906.
At least one of the lines of the French-owned company connected Ponce and Coamo through Juana Diaz. Off the main line near Ponce Playa ran a 6 1/2-km (4-mile) branch to the eastern bank of the Bucana. This engine -- apparently the very first for the railway established earlier that year -- was ordered from Baldwin by Arthur Koppel, then operating in Brussels.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 1 |
Locobase ID | 13070 |
Railroad | Compagnie Des Sucrerie on Porto Rico |
Country | USA-Puerto Rico |
Whyte | 0-4-4T |
Number in Class | 1 |
Road Numbers | 1 |
Gauge | Metre |
Number Built | 1 |
Builder | Burnham, Williams & Co |
Year | 1906 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 5 / 1.52 |
Engine Wheelbase (ft / m) | 17 / 5.18 |
Ratio of driving wheelbase to overall engine wheelbase | 0.29 |
Overall Wheelbase (engine & tender) (ft / m) | 17 / 5.18 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 32,000 / 14,515 |
Engine Weight (lbs / kg) | 44,000 / 19,958 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 600 / 2.27 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 27 / 13.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 33 / 838 |
Boiler Pressure (psi / kPa) | 160 / 1100 |
High Pressure Cylinders (dia x stroke) (in / mm) | 11" x 16" / 279x406 |
Tractive Effort (lbs / kg) | 7979 / 3619.22 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.01 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 83 - 1.75" / 44 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 8.75 / 2.67 |
Firebox Area (sq ft / m2) | 53 / 4.93 |
Grate Area (sq ft / m2) | 8 / 0.74 |
Evaporative Heating Surface (sq ft / m2) | 383 / 35.59 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 383 / 35.59 |
Evaporative Heating Surface/Cylinder Volume | 217.61 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1280 |
Same as above plus superheater percentage | 1280 |
Same as above but substitute firebox area for grate area | 8480 |
Power L1 | 3240 |
Power MT | 446.44 |