Data from Circulo de Estudios Ferrovarios del Uruguay (CEFU) website ([]), provided by Tabare Bordach. Updated link was [], last accessed 30 August 2018. Works numbers were 1197-1198.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | 3 |
| Locobase ID | 4814 |
| Railroad | |
| Country | Uruguay |
| Whyte | 0-6-0ST |
| Number in Class | 1 |
| Road Numbers | 3 |
| Gauge | Std |
| Number Built | 1 |
| Builder | Manning, Wardle |
| Year | 1890 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 10.25 / 3.12 |
| Engine Wheelbase (ft / m) | 10.25 / 3.12 |
| Ratio of driving wheelbase to overall engine wheelbase | 1 |
| Overall Wheelbase (engine & tender) (ft / m) | |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 36,680 / 16,638 |
| Engine Weight (lbs / kg) | 36,680 / 16,638 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 473 / 1.79 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 0.80 / 1 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 20 / 10 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 42 / 1067 |
| Boiler Pressure (psi / kPa) | 140 / 970 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 11" x 17" / 279x432 |
| Tractive Effort (lbs / kg) | 5828 / 2643.54 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 6.29 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 78 - 2" / 51 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 7.50 / 2.29 |
| Firebox Area (sq ft / m2) | 40 / 3.72 |
| Grate Area (sq ft / m2) | 7.50 / 0.70 |
| Evaporative Heating Surface (sq ft / m2) | 346 / 32.16 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 346 / 32.16 |
| Evaporative Heating Surface/Cylinder Volume | 185.04 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 1050 |
| Same as above plus superheater percentage | 1050 |
| Same as above but substitute firebox area for grate area | 5600 |
| Power L1 | 2862 |
| Power MT | 516.05 |