0-4-2 Steam Locomotives in Haiti

Cie de CF de la Plaine du Cul-de-Sac


Class Details by Steve Llanso of Sweat House Media

Class unknown (Locobase 15813)

Data from "Equipment & Supplies - Locomotive Building", Railroad Age Gazette, Vol 47, No 9 (27 August 1909), p. 387. See also Martin Coombs, Part 20 West Indian islands steam locomotive lists (other than Cuba), V. 1.04, June 2026, pp. 152-154, at [], last accessed 8 August 2026. Works numbers were 4424-4427 in October 1909.

Martin Coombs shows several photographs and a Porter description in his welcome addition to his masterwork of South and Central steam locomotives series.

The Pittsburgh builder classified this tank-tender engine as 2-B-SS-T4 and described it as a "special design for special conditions." One of the quartet bore the name "Sud", but Coombs could find no information on road numbers.

Principal Dimensions by Steve Llanso of Middle Run Media
Classunknown
Locobase ID15813
RailroadCie de CF de la Plaine du Cul-de-Sac (Central)
CountryHaiti
Whyte0-4-2T
Number in Class4
Road Numbers
Gauge2'6"
Number Built4
BuilderPorter
Year1909
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m)
Engine Wheelbase (ft / m)
Ratio of driving wheelbase to overall engine wheelbase
Overall Wheelbase (engine & tender) (ft / m)
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)52,000 / 23,587
Engine Weight (lbs / kg)60,000 / 27,216
Tender Loaded Weight (lbs / kg)12,000 / 5443
Total Engine and Tender Weight (lbs / kg)72,000 / 32,659
Tender Water Capacity (gals / ML)1000 / 3.79
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT)
Minimum weight of rail (calculated) (lb/yd / kg/m)43 / 21.50
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)40 / 1016
Boiler Pressure (psi / kPa)170 / 1160
High Pressure Cylinders (dia x stroke) (in / mm)13" x 18" / 330x457
Tractive Effort (lbs / kg)10,989 / 4984.53
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.73
Heating Ability
Tubes (number - dia) (in / mm)112 - 2" / 51
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)10 / 3.05
Firebox Area (sq ft / m2)58.90 / 5.47
Grate Area (sq ft / m2)13.20 / 1.23
Evaporative Heating Surface (sq ft / m2)630 / 58.53
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)630 / 58.53
Evaporative Heating Surface/Cylinder Volume227.83
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation2244
Same as above plus superheater percentage2244
Same as above but substitute firebox area for grate area10,013
Power L13789
Power MT321.28

All material Copyright © SteamLocomotive.com
Wes Barris