Data from "BBÖ Kh" in Wikipedia at [], last accessed 2 July 2024. See also See [] (original link), later "Kh 111" on the Club 760 website at [], last accessed 2 July 2024. Works number was 1519 in 1930.
Narrow-gauge tank engine built for the StLB's Wiez-Birkfeld-Ratten line coal trains. Max speed reached 25 kph (15.5 mph).
In 1943 she wasa exchanged for two U-class locomotives and moved to Murau where she worked until retirement. Club 760 bought her and sometime later she was added to the Frojach Museum's stud as a static-display engine..
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | Kh 111 / 499 |
| Locobase ID | 4830 |
| Railroad | StLB |
| Country | Austria |
| Whyte | 0-10-0T |
| Number in Class | 1 |
| Road Numbers | Kh 1 / Kh 101 / 499.01 |
| Gauge | 76 cm |
| Number Built | 1 |
| Builder | Krauss Linz |
| Year | 1930 |
| Valve Gear | Caprotti |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 13.62 / 4.15 |
| Engine Wheelbase (ft / m) | 13.62 / 4.15 |
| Ratio of driving wheelbase to overall engine wheelbase | 1 |
| Overall Wheelbase (engine & tender) (ft / m) | 13.62 / 4.15 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 73,414 / 33,100 |
| Engine Weight (lbs / kg) | 73,414 / 33,100 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 924 / 3.50 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1.50 / 1.32 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 24 / 12 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 32.30 / 800 |
| Boiler Pressure (psi / kPa) | 174 / 1200 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 15.75" x 15.75" / 400x400 |
| Tractive Effort (lbs / kg) | 17,890 / 8114.78 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.10 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | |
| Firebox Area (sq ft / m2) | 52.19 / 4.88 |
| Grate Area (sq ft / m2) | 13.02 / 1.21 |
| Evaporative Heating Surface (sq ft / m2) | 540 / 54.94 |
| Superheating Surface (sq ft / m2) | / 20.20 |
| Combined Heating Surface (sq ft / m2) | 540 / 75.14 |
| Evaporative Heating Surface/Cylinder Volume | 152.05 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 2265 |
| Same as above plus superheater percentage | 2265 |
| Same as above but substitute firebox area for grate area | 9081 |
| Power L1 | 2112 |
| Power MT | 317.12 |