2-4-0 Steam Locomotives in Brazil

Central do Rio Grande do Norte


Class Details by Steve Llanso of Sweat House Media

Class 14 (Locobase 13975)

Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 44, p. 143. Works number was 38626 in October 1912.

Locobase suspects that this little wood-burning 6-wheeler had been produced as stock and had been completed before it was sold to the EFCB.

Principal Dimensions by Steve Llanso of Middle Run Media
Class14
Locobase ID13975
RailroadCentral do Rio Grande do Norte
CountryBrazil
Whyte2-4-0
Number in Class1
Road Numbers14
GaugeMetre
Number Built1
BuilderBaldwin
Year1912
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m) 5.25 / 1.60
Engine Wheelbase (ft / m)10.92 / 3.33
Ratio of driving wheelbase to overall engine wheelbase 0.48
Overall Wheelbase (engine & tender) (ft / m)25.58 / 7.80
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)23,000 / 10,433
Engine Weight (lbs / kg)28,000 / 12,701
Tender Loaded Weight (lbs / kg)15,000 / 6804
Total Engine and Tender Weight (lbs / kg)43,000 / 19,505
Tender Water Capacity (gals / ML)600 / 2.27
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT)
Minimum weight of rail (calculated) (lb/yd / kg/m)19 / 9.50
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)33 / 838
Boiler Pressure (psi / kPa)150 / 1030
High Pressure Cylinders (dia x stroke) (in / mm)9" x 16" / 229x406
Tractive Effort (lbs / kg)5007 / 2271.14
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.59
Heating Ability
Tubes (number - dia) (in / mm)66 - 1.5" / 38
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)6 / 1.83
Firebox Area (sq ft / m2)27 / 2.51
Grate Area (sq ft / m2) 7.30 / 0.68
Evaporative Heating Surface (sq ft / m2)180 / 16.72
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)180 / 16.72
Evaporative Heating Surface/Cylinder Volume152.79
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation1095
Same as above plus superheater percentage1095
Same as above but substitute firebox area for grate area4050
Power L12206
Power MT422.90

All material Copyright © SteamLocomotive.com