Class 140 (Locobase 13778)

Data from Record of Recent Construction #54 (Baldwin Locomotive Works, 1905), p. 30-31; and DeGolyer, Volume 39, pp. 250+. Works numbers were 35777-35778 in December 1910 and 37476-37479, 37498-37500 in January 1912.

These Consolidations were called upon to ride on 25-kg/metre (50-lb/yard) rail, negotiate curve radii as tight as 266 ft (81 metres) and clear an 8-ft (2.44-m) loading gauge 33" (0.84 m) off the rail. Mogyana specified that the main rods drive the third adhesion axle. Inevitably, it seems, the design earned the stipulation "frames to be made heavier." ("Heavier than ..." may mean than the stock metre-gauge 2-8-0. It's a common request in Baldwin specs for locomotives destined to run on relatively poor tracks.

Principal Dimensions by Steve Llanso of Middle Run Media
Class140
Locobase ID13778
RailroadMogiana
CountryBrazil
Whyte2-8-0
Number in Class9
Road Numbers140-141, 164-170
GaugeMetre
Number Built9
BuilderBaldwin
Year1911
Valve GearWalschaert
Locomotive Length and Weight
Driver Wheelbase (ft / m)12.67 / 3.86
Engine Wheelbase (ft / m)19.92 / 6.07
Ratio of driving wheelbase to overall engine wheelbase 0.64
Overall Wheelbase (engine & tender) (ft / m)
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)85,000 / 38,555
Engine Weight (lbs / kg)100,000 / 45,359
Tender Loaded Weight (lbs / kg)50,000 / 22,680
Total Engine and Tender Weight (lbs / kg)150,000 / 68,039
Tender Water Capacity (gals / ML)2400 / 9.09
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT)
Minimum weight of rail (calculated) (lb/yd / kg/m)35 / 17.50
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)42 / 1067
Boiler Pressure (psi / kPa)160 / 1100
High Pressure Cylinders (dia x stroke) (in / mm)17.5" x 22" / 445x559
Tractive Effort (lbs / kg)21,817 / 9896.04
Factor of Adhesion (Weight on Drivers/Tractive Effort) 3.90
Heating Ability
Tubes (number - dia) (in / mm)200 - 2" / 51
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)11.83 / 3.61
Firebox Area (sq ft / m2)114 / 10.59
Grate Area (sq ft / m2)18 / 1.67
Evaporative Heating Surface (sq ft / m2)1341 / 124.58
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)1341 / 124.58
Evaporative Heating Surface/Cylinder Volume218.95
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation2880
Same as above plus superheater percentage2880
Same as above but substitute firebox area for grate area18,240
Power L13495
Power MT362.60

All material Copyright © SteamLocomotive.com