Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Vol 79, p.222. Works number was 59697 in November 1926.
Described as a switcher, this wood-burning Mogul tank was nonetheless a superheated engine with 8" (203 mm) piston valves. Like the other SOe do Bahia locomotives, this little locomotive later operated on the subsidiary Nazareth railway.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | 30 |
| Locobase ID | 15440 |
| Railroad | Sudoeste da Bahia |
| Country | Brazil |
| Whyte | 2-6-0T |
| Number in Class | 1 |
| Road Numbers | 30 |
| Gauge | Metre |
| Number Built | 1 |
| Builder | Baldwin |
| Year | 1926 |
| Valve Gear | Walschaert |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 9.67 / 2.95 |
| Engine Wheelbase (ft / m) | 16.67 / 5.08 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.58 |
| Overall Wheelbase (engine & tender) (ft / m) | 16.67 / 5.08 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 73,000 / 33,112 |
| Engine Weight (lbs / kg) | 85,000 / 38,555 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 1000 / 3.79 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 41 / 20.50 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 37 / 940 |
| Boiler Pressure (psi / kPa) | 180 / 1240 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 14" x 18" / 356x457 |
| Tractive Effort (lbs / kg) | 14,589 / 6617.47 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.00 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 72 - 2" / 51 |
| Flues (number - dia) (in / mm) | 12 - 5.375" / 137 |
| Flue/Tube length (ft / m) | 8.50 / 2.59 |
| Firebox Area (sq ft / m2) | 86 / 7.99 |
| Grate Area (sq ft / m2) | 13.10 / 1.22 |
| Evaporative Heating Surface (sq ft / m2) | 545 / 50.63 |
| Superheating Surface (sq ft / m2) | 114 / 10.59 |
| Combined Heating Surface (sq ft / m2) | 659 / 61.22 |
| Evaporative Heating Surface/Cylinder Volume | 169.94 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 2358 |
| Same as above plus superheater percentage | 2759 |
| Same as above but substitute firebox area for grate area | 18,112 |
| Power L1 | 6926 |
| Power MT | 627.50 |