2-6-2 Steam Locomotives in Chile

Cía. Carbonífera e Industrial


Class Details by Steve Llanso of Sweat House Media

Class 55? (Locobase 21335)

Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Volume 49, p. 175. See also Martin Coombs, Chilean steam locomotive lists, Part 1, Broad gauge locos (v2.64, March 2026), pp. 227-229 at []. Works numbers were 783-784 in 1953

Although the order may seem a bit late in the steam era, this Prairie duo illustrates all the gains that might be had by putting a trailing truck under the firebox. Compared to the decades-earlier -6-0s (Locobase 13989, Locobase 13127, Locobase 11417), all heating surface areas increased, sizable superheater, and heavier axle loading. A blurry image in a film seemed to show road number 55.

Principal Dimensions by Steve Llanso of Middle Run Media
Class55?
Locobase ID21335
RailroadCía. Carbonífera e Industrial
CountryChile
Whyte2-6-2
Number in Class2
Road Numbers55?
Gauge5'6"
Number Built2
BuilderMitsubishi
Year1953
Valve GearWalschaert
Locomotive Length and Weight
Driver Wheelbase (ft / m)10.60 / 3.23
Engine Wheelbase (ft / m)26.71 / 8.14
Ratio of driving wheelbase to overall engine wheelbase 0.40
Overall Wheelbase (engine & tender) (ft / m)51.18 / 15.60
Axle Loading (Maximum Weight per Axle) (lbs / kg)29,101 / 13,200
Weight on Drivers (lbs / kg)86,862 / 39,400
Engine Weight (lbs / kg)127,647 / 57,900
Tender Loaded Weight (lbs / kg)91,492 / 41,500
Total Engine and Tender Weight (lbs / kg)219,139 / 99,400
Tender Water Capacity (gals / ML)3960 / 15
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 6.60 / 6
Minimum weight of rail (calculated) (lb/yd / kg/m)48 / 24
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)55.10 / 1400
Boiler Pressure (psi / kPa)202.70 / 1380
High Pressure Cylinders (dia x stroke) (in / mm)18.9" x 24.02" / 480x610
Tractive Effort (lbs / kg)26,830 / 12169.90
Factor of Adhesion (Weight on Drivers/Tractive Effort) 3.24
Heating Ability
Tubes (number - dia) (in / mm)71 - 2.008" / 51
Flues (number - dia) (in / mm)22 - 5" / 127
Flue/Tube length (ft / m)14.50 / 4.42
Firebox Area (sq ft / m2)107.64 / 10
Grate Area (sq ft / m2)24.22 / 2.25
Evaporative Heating Surface (sq ft / m2)1024 / 95.10
Superheating Surface (sq ft / m2)313 / 29.10
Combined Heating Surface (sq ft / m2)1337 / 124.20
Evaporative Heating Surface/Cylinder Volume131.29
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation4909
Same as above plus superheater percentage6039
Same as above but substitute firebox area for grate area26,837
Power L110,451
Power MT795.76

All material Copyright © SteamLocomotive.com
Wes Barris