Data from "Locomotora Tipo-c Plano General 10,352" from scans supplied by by Senor Raul Moroni of Santiago, archived on [], last accessed 1 May 2022. See also Martin Coombs, "Chilean Steam Locomotive List - Parte 4", Sub-metric gauge locos, pp. 220-222, downloaded from [], last accessed 8 April 2022. Works numbers were 1859-1862 in 1912.
A 1912 request for bids on six Tipo-bs and four Tipp-cs induced replies from Arnold Jung, Berliner Maschinenbau, Borsig, Henschel, Orenstein & Koppel, and American Locomotive Company. Jung won the contract, which was signed on 15 May 1912.
If Tipo-a (Locobase 21020) was small, and Tipo-b tiny, then Tipo-c was minute.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | Tipo-c |
| Locobase ID | 21022 |
| Railroad | Chilean State Railways (EFE) |
| Country | Chile |
| Whyte | 0-4-0T |
| Number in Class | 6 |
| Road Numbers | 24-27/46-48/5046-5048, 5051, 5056 |
| Gauge | 60 cm |
| Number Built | 6 |
| Builder | Jung |
| Year | 1912 |
| Valve Gear | Heusinger |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 3.94 / 1.20 |
| Engine Wheelbase (ft / m) | 3.94 / 1.20 |
| Ratio of driving wheelbase to overall engine wheelbase | 1 |
| Overall Wheelbase (engine & tender) (ft / m) | 3.94 / 1.20 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 19,180 / 8700 |
| Engine Weight (lbs / kg) | 20,503 / 9300 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 185 / 0.70 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 0.50 / 0.50 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 16 / 8 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 22.80 / 579 |
| Boiler Pressure (psi / kPa) | 159.50 / 1100 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 8.27" x 11.81" / 210x300 |
| Tractive Effort (lbs / kg) | 4803 / 2178.61 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.99 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 76 - 1.575" / 40 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 5.91 / 1.80 |
| Firebox Area (sq ft / m2) | 19.81 / 1.84 |
| Grate Area (sq ft / m2) | 4.31 / 0.40 |
| Evaporative Heating Surface (sq ft / m2) | 195 / 18.12 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 195 / 18.12 |
| Evaporative Heating Surface/Cylinder Volume | 265.58 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 687 |
| Same as above plus superheater percentage | 687 |
| Same as above but substitute firebox area for grate area | 3160 |
| Power L1 | 2427 |
| Power MT | 557.94 |