Data from "Recent Baldwin Locomotives for Export", Railway Gazette, Volume 61, No. 11 (15 September 1916), p. 465-466. See also DeGolyer, Volume 60, pp. 180. Works numbers were 43651-43654 in July 1916.
The Canton-Hankow took delivery of ten locomotives in 1916, all with Belpaire fireboxes. Unlike the 2-8-0s (Locobase 13443), the 4-6-0s had their grates located inside the frames. They had 11" (179 mm) piston valves.
See Locobase 13445 for the two 0-6-0s.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | unknown |
| Locobase ID | 13444 |
| Railroad | Canton-Hankow |
| Country | China |
| Whyte | 4-6-0 |
| Number in Class | 4 |
| Road Numbers | |
| Gauge | Std |
| Number Built | 4 |
| Builder | Baldwin |
| Year | 1916 |
| Valve Gear | Walschaert |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 14.75 / 4.50 |
| Engine Wheelbase (ft / m) | 28 / 8.53 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.53 |
| Overall Wheelbase (engine & tender) (ft / m) | 55.60 / 16.95 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 113,900 / 51,664 |
| Engine Weight (lbs / kg) | 159,700 / 72,439 |
| Tender Loaded Weight (lbs / kg) | 108,976 / 45,949 |
| Total Engine and Tender Weight (lbs / kg) | 268,676 / 118,388 |
| Tender Water Capacity (gals / ML) | 5100 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 63 / 31.50 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 66 / 1676 |
| Boiler Pressure (psi / kPa) | 160 / 1100 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 21" x 26" / 533x660 |
| Tractive Effort (lbs / kg) | 23,627 / 10717.04 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.82 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 137 - 2" / 51 |
| Flues (number - dia) (in / mm) | 22 - 5.375" / 137 |
| Flue/Tube length (ft / m) | 15.62 / 4.76 |
| Firebox Area (sq ft / m2) | 185 / 17.19 |
| Grate Area (sq ft / m2) | 31.80 / 2.95 |
| Evaporative Heating Surface (sq ft / m2) | 1781 / 165.46 |
| Superheating Surface (sq ft / m2) | 404 / 37.53 |
| Combined Heating Surface (sq ft / m2) | 2185 / 202.99 |
| Evaporative Heating Surface/Cylinder Volume | 170.87 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 5088 |
| Same as above plus superheater percentage | 6004 |
| Same as above but substitute firebox area for grate area | 34,928 |
| Power L1 | 10,709 |
| Power MT | 621.84 |