Data from Baldwin Locomotive Works Specification for Engines, as digitized by the DeGolyer Library of Southern Methodist University, Volume 20, p. 262. Works numbers were 15289-15292 in April 1897.
The Imperial Chinese railway was funded with British capital under a Chinese-British loan agreement signed 10 October 1898. It soon was renamed the Peking-Mukden. This quartet was renumbered 43-46 and served the railway when the Peking-Tientsin section opened in 1897.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | 39 |
| Locobase ID | 12235 |
| Railroad | Imperial Chinese / Peking-Mukden |
| Country | China |
| Whyte | 2-6-0 |
| Number in Class | 4 |
| Road Numbers | 39-42/43-46 |
| Gauge | Std |
| Number Built | 4 |
| Builder | Burnham, Williams & Co |
| Year | 1897 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 15 / 4.57 |
| Engine Wheelbase (ft / m) | 23.25 / 7.09 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.65 |
| Overall Wheelbase (engine & tender) (ft / m) | |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 107,000 / 48,534 |
| Engine Weight (lbs / kg) | 129,000 / 58,513 |
| Tender Loaded Weight (lbs / kg) | 96,000 / 43,545 |
| Total Engine and Tender Weight (lbs / kg) | 225,000 / 102,058 |
| Tender Water Capacity (gals / ML) | 4800 / 18.18 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 59 / 29.50 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 60 / 1524 |
| Boiler Pressure (psi / kPa) | 150 / 1030 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 19" x 24" / 483x610 |
| Tractive Effort (lbs / kg) | 18,411 / 8351.10 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.81 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 238 - 2" / 51 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 12 / 3.66 |
| Firebox Area (sq ft / m2) | 123.20 / 11.45 |
| Grate Area (sq ft / m2) | 24 / 2.23 |
| Evaporative Heating Surface (sq ft / m2) | 1608 / 149.44 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 1608 / 149.44 |
| Evaporative Heating Surface/Cylinder Volume | 204.17 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 3600 |
| Same as above plus superheater percentage | 3600 |
| Same as above but substitute firebox area for grate area | 18,480 |
| Power L1 | 4236 |
| Power MT | 261.83 |