Data from Titre Exposition universelle internationale de 1878 a Paris. Rapports du jury internationale..Volume Groupe VI - Classe 64. Rapport sur le materiel des chemins de fer. p. 55 (cnum.cnam.fr/CGI/fpage.cgi?8XAE277-11.1/54/100/312/0/0 (accessed 1 September 2005) table and page 91. Works numbers were 1920-1926 in 1875.
This tiny little tank was offered for "travaux agricole", agricultural work on a 31 1/2"-gauge railway. The only Cail 0-4-0Ts on the production list are the seven shown in 1875.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | 211 |
| Locobase ID | 7390 |
| Railroad | Exploitation agricole |
| Country | France |
| Whyte | 0-4-0T |
| Number in Class | 1 |
| Road Numbers | 1-7 |
| Gauge | 80 cm |
| Number Built | 1 |
| Builder | Cail |
| Year | 1878 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 2.95 / 0.90 |
| Engine Wheelbase (ft / m) | 2.95 / 0.90 |
| Ratio of driving wheelbase to overall engine wheelbase | 1 |
| Overall Wheelbase (engine & tender) (ft / m) | 2.95 / 0.90 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 8157 / 3700 |
| Engine Weight (lbs / kg) | 8157 / 3700 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 84 / 0.32 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 0.20 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 7 / 3.50 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 23.60 / 599 |
| Boiler Pressure (psi / kPa) | 130.50 / 900 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 5.91" x 9.45" / 150x240 |
| Tractive Effort (lbs / kg) | 1551 / 703.52 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.26 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 37 - 1.575" / 40 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 4.43 / 1.35 |
| Firebox Area (sq ft / m2) | 12.27 / 1.14 |
| Grate Area (sq ft / m2) | 1.94 / 0.18 |
| Evaporative Heating Surface (sq ft / m2) | 81 / 7.53 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 81 / 7.53 |
| Evaporative Heating Surface/Cylinder Volume | 269.96 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 253 |
| Same as above plus superheater percentage | 253 |
| Same as above but substitute firebox area for grate area | 1601 |
| Power L1 | 2435 |
| Power MT | 1316.23 |