Data from A. Sampite, Les Chemins de Fer a Faible Trafic en France (Paris: Baudry et Cie, 1888), p. 49. See also [] for a history of these Freycinet Plan railways and Wikipedia: [] (accessed 2 February 2008).
The Reseau d'Interet Local CF de l'HTrault was a network of secondary lines along the Gulf of Lyon in Southeast France. Sampite provides a summary of all the locomotives then in service on any of the lines and Wikipedia fills in the blanks. Note that none of the series of locomotives (Locobase 9159-9164) had either boiler pressure or grate area. The boiler pressure is an estimate.
This set of Grafenstadens served the Palavas line (Palavas was an up-and-coming beach attraction) until 1917.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | 1 |
| Locobase ID | 9159 |
| Railroad | Montpelier a Palavas |
| Country | France |
| Whyte | 0-4-0T |
| Number in Class | 4 |
| Road Numbers | 1-4 |
| Gauge | Std |
| Number Built | 4 |
| Builder | Grafenstaden |
| Year | 1872 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | |
| Engine Wheelbase (ft / m) | |
| Ratio of driving wheelbase to overall engine wheelbase | |
| Overall Wheelbase (engine & tender) (ft / m) | |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 51,147 / 23,200 |
| Engine Weight (lbs / kg) | 51,147 / 23,200 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 43 / 21.50 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 51.20 / 1300 |
| Boiler Pressure (psi / kPa) | 123.30 / 850 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 11.81" x 18.11" / 300x460 |
| Tractive Effort (lbs / kg) | 5170 / 2345.08 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 9.89 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | |
| Firebox Area (sq ft / m2) | 41.96 / 3.90 |
| Grate Area (sq ft / m2) | |
| Evaporative Heating Surface (sq ft / m2) | 521 / 48.40 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 521 / 48.40 |
| Evaporative Heating Surface/Cylinder Volume | 226.90 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | |
| Same as above plus superheater percentage | |
| Same as above but substitute firebox area for grate area | 5174 |
| Power L1 | 3349 |
| Power MT | 288.71 |