Data from Christian Lindecke's [] and from the Buntbahn site [], both accessed 1 Jan 2007. See Doug Self's description of the Hagans oscillating-lever, all-adhesion system at []
This was a Schwinghebel-Lokomotive, a Hagans design in which the coupled axle were grouped under the boiler and the carrying axles in a swivelling bogie under the tender.
First to operate this class was the Upper Silesian system of narrow-gauge railway. The KPEV later gave the class its T36 designation. By the time the Rueger Kleinbahn owned one of the locomotives, it had had the linking-levers removed and its gauge changed to 750 mm.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | K35.6 / T36 |
| Locobase ID | 8049 |
| Railroad | Oberschlesischen Schmalspurbahnen |
| Country | Germany |
| Whyte | 0-6-4T |
| Number in Class | 4 |
| Road Numbers | 99 4621 |
| Gauge | Metre |
| Number Built | 4 |
| Builder | Hagans |
| Year | 1897 |
| Valve Gear | Heusinger |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 5.81 / 1.77 |
| Engine Wheelbase (ft / m) | 15.26 / 4.65 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.38 |
| Overall Wheelbase (engine & tender) (ft / m) | 15.26 / 4.65 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | |
| Engine Weight (lbs / kg) | 59,966 / 27,200 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 660 / 2.50 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1.10 / 1 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 31.90 / 810 |
| Boiler Pressure (psi / kPa) | 174 / 1200 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 13.78" x 15.75" / 350x400 |
| Tractive Effort (lbs / kg) | 13,866 / 6289.52 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | |
| Firebox Area (sq ft / m2) | 47.47 / 4.41 |
| Grate Area (sq ft / m2) | 11.84 / 1.10 |
| Evaporative Heating Surface (sq ft / m2) | 555 / 51.60 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 555 / 51.60 |
| Evaporative Heating Surface/Cylinder Volume | 204.14 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 2060 |
| Same as above plus superheater percentage | 2060 |
| Same as above but substitute firebox area for grate area | 8260 |
| Power L1 | 2696 |
| Power MT | |