Data from Ernest Taillard, Exposition Universelle de Paris de 1867-Chemins de Fer-Les Locomotives et le Materiel de Transport, 1ie Volume (Paris: Dunod, 1867), pp. 27-31.
As the driver diameter suggests, this was a mixed-traffic locomotive. According to Taillard, among other features was the lack of pumps for feeding water into the boiler; instead, the engine used two Krauss injectors, which were unequal to the task. The firebox was a coke-burner that had two stages, the exhaust was variable, and the two safety-balves were fixed, one on the dome and the other on the firebox.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | unknown |
| Locobase ID | 11287 |
| Railroad | |
| Country | Prussia |
| Whyte | 0-4-2 |
| Number in Class | |
| Road Numbers | |
| Gauge | Std |
| Number Built | |
| Builder | Borsig |
| Year | 1867 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | |
| Engine Wheelbase (ft / m) | 13.39 / 4.08 |
| Ratio of driving wheelbase to overall engine wheelbase | |
| Overall Wheelbase (engine & tender) (ft / m) | |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | 27,007 / 12,250 |
| Weight on Drivers (lbs / kg) | 50,706 / 23,000 |
| Engine Weight (lbs / kg) | 73,414 / 33,300 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 42 / 21 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 60 / 1524 |
| Boiler Pressure (psi / kPa) | 116 / 800 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 15.98" x 22.01" / 406x559 |
| Tractive Effort (lbs / kg) | 9236 / 4189.38 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.49 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 194 - 1.811" / 46 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 11.32 / 3.45 |
| Firebox Area (sq ft / m2) | 72.85 / 6.77 |
| Grate Area (sq ft / m2) | 18.51 / 1.72 |
| Evaporative Heating Surface (sq ft / m2) | 1001 / 93.07 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 1001 / 93.07 |
| Evaporative Heating Surface/Cylinder Volume | 195.92 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 2147 |
| Same as above plus superheater percentage | 2147 |
| Same as above but substitute firebox area for grate area | 8451 |
| Power L1 | 3100 |
| Power MT | 269.57 |