Data from Graham Davies at members.tripod.co.uk/Graham_Davies/index-51.html. See also "Railways in West Wales Part 1B - Pembrokeshire - the Mainline Railways" on Roger Farnworth's blog at [], last accessed 22 September 2022. Works numbers were 1713 and 1756 in 1866.
Locobase 4898 shows the Pembroke & Tenby #3, which duplicated the standard Sharp, Stewart six-wheel passenger engine design. Davies wrote that the P&T was to take two of three in the order with the other going to the M&M. But the P&T only operated one of the the three. Martin Coombs's builders list shows the 1713 as the first in SS order E485 and 1756 (named Lady Elisabeth) as the second.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | Carmathen |
| Locobase ID | 21093 |
| Railroad | Manchester & Milford |
| Country | Great Britain |
| Whyte | 2-4-0 |
| Number in Class | 2 |
| Road Numbers | 2-3 |
| Gauge | Std |
| Number Built | 2 |
| Builder | Sharp, Stewart |
| Year | 1866 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 6.50 / 1.98 |
| Engine Wheelbase (ft / m) | 14.25 / 4.34 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.46 |
| Overall Wheelbase (engine & tender) (ft / m) | |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | |
| Engine Weight (lbs / kg) | 55,552 / 25,198 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 1440 / 5.45 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 3.30 / 3 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 66 / 1676 |
| Boiler Pressure (psi / kPa) | 120 / 830 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 16" x 20" / 406x508 |
| Tractive Effort (lbs / kg) | 7913 / 3589.28 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 157 - 2" / 51 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 10.25 |
| Firebox Area (sq ft / m2) | 71.40 / 6.64 |
| Grate Area (sq ft / m2) | |
| Evaporative Heating Surface (sq ft / m2) | 915 / 85.04 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 915 / 85.04 |
| Evaporative Heating Surface/Cylinder Volume | 196.60 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | |
| Same as above plus superheater percentage | |
| Same as above but substitute firebox area for grate area | 8568 |
| Power L1 | 3608 |
| Power MT | |