Data from Wiener (1930). Works number was 906 in 1903.
One of smallest articulateds to be found in Locobase, this design used the Kitson-Meyer arrangement of both sets of drivers leading their cylinders under a common frame and boiler.
The industrial-locomotive website [] (accessed 15 Jan 2006) has a listing of Barclay engines. This particular unit was owned by Glasgow-based James Howden & Co, which sent it to Limni in Greece in May 1903.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | KAKAVOS |
| Locobase ID | 3626 |
| Railroad | Anglo-Greek Magnesite |
| Country | Greece |
| Whyte | 0-4-0+0-4-0T |
| Number in Class | 1 |
| Road Numbers | 3 |
| Gauge | 2'6" |
| Number Built | 1 |
| Builder | Andrew Barclay |
| Year | 1903 |
| Valve Gear | Walschaert |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 8 / 1.22 |
| Engine Wheelbase (ft / m) | 17 / 5.18 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.47 |
| Overall Wheelbase (engine & tender) (ft / m) | |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 67,200 / 30,481 |
| Engine Weight (lbs / kg) | 67,200 / 30,481 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 800 / 2.52 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1.70 / 1 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 28 / 14 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 27.50 / 699 |
| Boiler Pressure (psi / kPa) | 165 / 1140 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 9" x 15" / 229x381 (4) |
| Tractive Effort (lbs / kg) | 12,393 / 5621.38 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.42 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 115 - 1.75" / 44 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 9.81 / 2.99 |
| Firebox Area (sq ft / m2) | 48 / 4.46 |
| Grate Area (sq ft / m2) | 8.50 / 0.79 |
| Evaporative Heating Surface (sq ft / m2) | 508 / 47.21 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 508 / 47.21 |
| Evaporative Heating Surface/Cylinder Volume | 229.98 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 1403 |
| Same as above plus superheater percentage | 1403 |
| Same as above but substitute firebox area for grate area | 7920 |
| Power L1 | 2561 |
| Power MT | 336.07 |