Data from [] . See Indra Krishnamurti at [] for building dates and numbers both of predecessor railways and the Indonesian State Railways. See also "Lokomotif C16" in Wikipedia (translated by Google) at [], last accessed 27 August 2026. Works numbers were 2467-2468 in 1899, 2716-2719 in 1901
Located in central Java and equidistant from the ports of Semarang (to the north on the Java Sea) and Yogyakarta (to the south on the Indian Ocean), Malegang served both as a military center and economic hub. The Dutch East Indies government chose it, according to Wikipedia "due to its strategic location, pleasant climate, and beautiful scenery."
Its first leg--47 km (29 miles) south to Yogyakarta--opened in 1898. A later branch from Secang northwest 15 km (9.3 mile) to Temanggung stopped at every station in a near-constant climb. Wikipedia notes that travel time could reach two hours. Maximum allowable speed waas 55 kph (34 mph).
These outside-framed oil or teak burners used Karl Golsdorf's all-axle lateral motion system that allowed each axle to negotiate large-radius curves. Between 1924 and 1931, the NIS superheated seven of the class (251 was not included, apparently).
C1603 went display at the Ambarawa Museum. All others were scrapped.
Data from [] . See also TecBook reprint of Sachsische Maschinenfabrik Richard Hartmann: alle 1910 catalogue, p. 34, previewed in Google Books (last accessed 11 December 2010).
See Indra Krishnamurti at [] for building dates and numbers both of predecessor railways and the Indonesian State Railways. The catalogue photograph clearly shows the outside plate frame and the evenly spaced drivers under the firebox and boiler.
The lone C23 delivered in 1908 seems to have been identical except for a slight decrease in weight to 51,115 lb.
Data from []. . See Indra Krishnamurti at [] for building dates and numbers both of predecessor railways and the Indonesian State Railways.
| Principal Dimensions by Steve Llanso of Middle Run Media | |||
|---|---|---|---|
| Class | C16 | C17 | C18 |
| Locobase ID | 4728 | 4729 | 4730 |
| Railroad | Nederlandsch-Indische Spoorweg Mij | Nederlandsch-Indische Spoorweg Mij | Nederlandsch-Indische Spoorweg Mij |
| Country | Indonesia | Indonesia | Indonesia |
| Whyte | 0-6-0T | 0-6-0T | 0-6-0T |
| Number in Class | 8 | 5 | 1 |
| Road Numbers | 250-257/C1601-C1607 | 251, 253+/C1701-1705 | 259/C1801 |
| Gauge | 3'6" | 3'6" | 3'6" |
| Number Built | 8 | 5 | 1 |
| Builder | Hartmann | Hartmann | Hartmann |
| Year | 1924 | 1899 | 1908 |
| Valve Gear | Stephenson | Stephenson | |
| Locomotive Length and Weight | |||
| Driver Wheelbase (ft / m) | 11.15 / 3.40 | ||
| Engine Wheelbase (ft / m) | 11.15 / 3.40 | ||
| Ratio of driving wheelbase to overall engine wheelbase | 1 | ||
| Overall Wheelbase (engine & tender) (ft / m) | 11.15 / 3.40 | ||
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | 18,827 / 8540 | ||
| Weight on Drivers (lbs / kg) | 56,350 / 25,560 | 55,909 / 25,360 | 57,541 / 26,100 |
| Engine Weight (lbs / kg) | 56,350 / 25,560 | 55,909 / 25,360 | 57,541 / 26,100 |
| Tender Loaded Weight (lbs / kg) | |||
| Total Engine and Tender Weight (lbs / kg) | |||
| Tender Water Capacity (gals / ML) | 792 / 3 | 713 / 2.70 | |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |||
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 31 / 15.50 | 31 / 15.50 | 32 / 16 |
| Geometry Relating to Tractive Effort | |||
| Driver Diameter (in / mm) | 41.70 / 1058 | 41.30 / 1050 | 41.70 / 1058 |
| Boiler Pressure (psi / kPa) | 176.30 / 1200 | 179.80 / 1240 | 174 / 1200 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 13.39" x 15.75" / 340x400 | 13.39" x 15.75" / 340x400 | 13.78" x 15.75" / 350x400 |
| Tractive Effort (lbs / kg) | 10,148 / 4603.06 | 10,450 / 4740.05 | 10,607 / 4811.26 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.55 | 5.35 | 5.42 |
| Heating Ability | |||
| Tubes (number - dia) (in / mm) | |||
| Flues (number - dia) (in / mm) | |||
| Flue/Tube length (ft / m) | |||
| Firebox Area (sq ft / m2) | 50.57 / 4.70 | ||
| Grate Area (sq ft / m2) | 9.69 / 0.90 | 9.68 / 0.90 | 9.68 / 0.90 |
| Evaporative Heating Surface (sq ft / m2) | 348 / 32.30 | 426 / 39.60 | 350 / 32.50 |
| Superheating Surface (sq ft / m2) | 156 / 14.50 | 175 / 16.30 | |
| Combined Heating Surface (sq ft / m2) | 504 / 46.80 | 426 / 39.60 | 525 / 48.80 |
| Evaporative Heating Surface/Cylinder Volume | 135.57 | 165.96 | 128.74 |
| Computations Relating to Power Output (More Information) | |||
| Robert LeMassena's Power Computation | 1708 | 1740 | 1684 |
| Same as above plus superheater percentage | 2238 | 1740 | 2240 |
| Same as above but substitute firebox area for grate area | 9092 | ||
| Power L1 | 3273 | ||
| Power MT | 387.19 | ||