Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 16, p. 184. Works numbers numbers were 11524 in January 1891 and 11719 in March.
This pair of double-ended, wood-burners lettered as shown in the Railroad description, but the spec described the buyer as Mexican Pacific. Their Radley & Hunter stacks were intended to reduce the chance fo trackside fires. Specs called for the total engine & tender wheelbase "not to exceed 48 ft."
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | 1 |
| Locobase ID | 11719 |
| Railroad | Mexican & Central American |
| Country | Mexico |
| Whyte | 2-4-2 |
| Number in Class | 2 |
| Road Numbers | 1-2 |
| Gauge | 3' |
| Number Built | 2 |
| Builder | Burnham, Williams & Co |
| Year | 1891 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 5.67 / 1.73 |
| Engine Wheelbase (ft / m) | 20.92 / 6.38 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.27 |
| Overall Wheelbase (engine & tender) (ft / m) | 20.92 / 6.38 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 36,000 / 16,329 |
| Engine Weight (lbs / kg) | 56,000 / 25,401 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 1600 / 6.06 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 30 / 15 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 46 / 1168 |
| Boiler Pressure (psi / kPa) | 130 / 900 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 14" x 18" / 356x457 |
| Tractive Effort (lbs / kg) | 8475 / 3844.20 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.25 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 147 - 1.75" / 44 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 9.25 / 2.82 |
| Firebox Area (sq ft / m2) | 84.80 / 7.88 |
| Grate Area (sq ft / m2) | 6.25 / 0.58 |
| Evaporative Heating Surface (sq ft / m2) | 702 / 65.24 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 702 / 65.24 |
| Evaporative Heating Surface/Cylinder Volume | 218.69 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 813 |
| Same as above plus superheater percentage | 813 |
| Same as above but substitute firebox area for grate area | 11,024 |
| Power L1 | 3496 |
| Power MT | 428.19 |