Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Vol 72, pp. 96+. Works number was 58236 in February 1925.
For service on the 25 miles (40 km) of railroad operated by this railway & port company, this little Mogul provided a little more power than the switcher shown in Locobase 15084.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | Saltur |
| Locobase ID | 15263 |
| Railroad | Compania de Ferrocarril y Muelle de Pimentel |
| Country | Peru |
| Whyte | 2-6-0 |
| Number in Class | 1 |
| Road Numbers | 6 |
| Gauge | 3' |
| Number Built | 1 |
| Builder | Baldwin |
| Year | 1925 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 9.33 / 2.84 |
| Engine Wheelbase (ft / m) | 15.50 / 4.72 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.60 |
| Overall Wheelbase (engine & tender) (ft / m) | 38 / 11.58 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 47,500 / 21,546 |
| Engine Weight (lbs / kg) | 56,000 / 25,401 |
| Tender Loaded Weight (lbs / kg) | 48,000 / 21,772 |
| Total Engine and Tender Weight (lbs / kg) | 104,000 / 47,173 |
| Tender Water Capacity (gals / ML) | 2000 / 7.58 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 5 / 5 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 26 / 13 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 38 / 965 |
| Boiler Pressure (psi / kPa) | 165 / 1140 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 13" x 18" / 330x457 |
| Tractive Effort (lbs / kg) | 11,227 / 5092.49 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.23 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 86 - 2" / 51 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 8.25 / 2.51 |
| Firebox Area (sq ft / m2) | 50 / 4.65 |
| Grate Area (sq ft / m2) | 10.50 / 0.98 |
| Evaporative Heating Surface (sq ft / m2) | 418 / 38.83 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 418 / 38.83 |
| Evaporative Heating Surface/Cylinder Volume | 151.16 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 1733 |
| Same as above plus superheater percentage | 1733 |
| Same as above but substitute firebox area for grate area | 8250 |
| Power L1 | 2524 |
| Power MT | 351.44 |