Data from "Tank Frame Locomotives", Record of Recent Construction #93 (Baldwin Locomotive Works, 1918), p.10. See also DeGolyer, Vol 57, pp. 384. Works number was 43123 in March 1916.
See Locobase 10996 for a short description of this small tank-engine design sold to several industrial, mining, and agricultural companies.
Small wood-burner that had three axles presumably to disperse the weight on very light rail. Its Radley & Hunter stack's spark-arresting system resembled a spinning top. Appearances proved to be predictive as the "top's" design imparted a rotary motion to the sparks to encourage their breaking up and extinction before they left the stack.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | unknown |
| Locobase ID | 11003 |
| Railroad | International Engineering & Trading |
| Country | Russia |
| Whyte | 0-6-0WT |
| Number in Class | 1 |
| Road Numbers | |
| Gauge | 75 cm |
| Number Built | 1 |
| Builder | Baldwin |
| Year | 1916 |
| Valve Gear | Marshall |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 4.67 / 1.42 |
| Engine Wheelbase (ft / m) | 4.67 / 1.42 |
| Ratio of driving wheelbase to overall engine wheelbase | 1 |
| Overall Wheelbase (engine & tender) (ft / m) | 4.67 / 1.42 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 22,850 / 10,365 |
| Engine Weight (lbs / kg) | 22,850 / 10,365 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 200 / 0.76 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 13 / 6.50 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 23 / 584 |
| Boiler Pressure (psi / kPa) | 176 / 1210 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 8" x 12" / 203x305 |
| Tractive Effort (lbs / kg) | 4995 / 2265.70 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.57 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 66 - 1.75" / 44 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 7.67 / 2.34 |
| Firebox Area (sq ft / m2) | 26 / 2.42 |
| Grate Area (sq ft / m2) | 4.90 / 0.46 |
| Evaporative Heating Surface (sq ft / m2) | 255 / 23.69 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 255 / 23.69 |
| Evaporative Heating Surface/Cylinder Volume | 365.26 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 862 |
| Same as above plus superheater percentage | 862 |
| Same as above but substitute firebox area for grate area | 4576 |
| Power L1 | 3721 |
| Power MT | 1077.03 |