Data from "Russian Goods Locomotive," Engineering, Volume 18 (25 December 1874), pp. 490-491.
Engineering noted a few differences from the typical goods locomotive of the time. One was a slight backwards rake to the firebox's back wall, which slightly increased the grate area. Otherwise, the engine had a common profile that had the dome well forward, just behind the stack and just ahead of a small drum-shaped sandbox. The stack had a flared spark-arresting casing around the straight pipe. A much smaller onion dome sat over over the firebox and inside the cab. One criticism concerned the reversing lever, which was "...very short, and has a most unusually -- and we consider inconveniently -- large angular range."
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | unknown |
| Locobase ID | 13566 |
| Railroad | St Petersburg-Warsaw |
| Country | Russia |
| Whyte | 0-6-0 |
| Number in Class | |
| Road Numbers | |
| Gauge | 5' |
| Number Built | |
| Builder | StPW |
| Year | 1874 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 11.15 / 3.40 |
| Engine Wheelbase (ft / m) | 11.15 / 3.40 |
| Ratio of driving wheelbase to overall engine wheelbase | 1 |
| Overall Wheelbase (engine & tender) (ft / m) | |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 70,548 / 32,000 |
| Engine Weight (lbs / kg) | 70,548 / 32,000 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 39 / 19.50 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 51.20 / 1300 |
| Boiler Pressure (psi / kPa) | 124.70 / 860 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 17.32" x 24.02" / 440x610 |
| Tractive Effort (lbs / kg) | 14,917 / 6766.25 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.73 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 162 - 1.969" / 50 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 13.78 / 4.20 |
| Firebox Area (sq ft / m2) | 90.42 / 8.40 |
| Grate Area (sq ft / m2) | 16.15 / 1.50 |
| Evaporative Heating Surface (sq ft / m2) | 1249 / 116 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 1249 / 116 |
| Evaporative Heating Surface/Cylinder Volume | 190.69 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 2014 |
| Same as above plus superheater percentage | 2014 |
| Same as above but substitute firebox area for grate area | 11,275 |
| Power L1 | 2764 |
| Power MT | 259.12 |