Data from Baldwin Locomotive Works Negative 7786 as archived at Flicker, [], last accessed 22 December 2012. See also DeGolyer, Vol 63, pp. 265. Works number was 54136 in November 1920.
A comment on the flickr website from a "PR RR Historian" gave a full account of this locomotive's checkered history:"For reasons never satisfactorily given, this locomotive, the second # 1 for Central Juncos [of Las Piedras, PR], only worked the railroad for a very short period of time before being sold off of the Island to a mill in the Dominican Republic in 1922."
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | 1 |
| Locobase ID | 14761 |
| Railroad | Juncos Central |
| Country | USA |
| Whyte | 2-6-0 |
| Number in Class | 1 |
| Road Numbers | 1 |
| Gauge | 2'6" |
| Number Built | 1 |
| Builder | Baldwin |
| Year | 1920 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 7 / 2.13 |
| Engine Wheelbase (ft / m) | 13.50 / 4.11 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.52 |
| Overall Wheelbase (engine & tender) (ft / m) | 38.33 / 11.68 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 40,000 / 18,144 |
| Engine Weight (lbs / kg) | 46,000 / 20,865 |
| Tender Loaded Weight (lbs / kg) | 44,000 / 19,958 |
| Total Engine and Tender Weight (lbs / kg) | 90,000 / 40,823 |
| Tender Water Capacity (gals / ML) | 2000 / 7.58 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 4 / 4 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 22 / 11 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 36 / 914 |
| Boiler Pressure (psi / kPa) | 170 / 1170 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 12" x 16" / 305x406 |
| Tractive Effort (lbs / kg) | 9248 / 4194.83 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.33 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 73 - 2" / 51 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 11.33 / 3.45 |
| Firebox Area (sq ft / m2) | 39 / 3.62 |
| Grate Area (sq ft / m2) | 8 / 0.74 |
| Evaporative Heating Surface (sq ft / m2) | 469 / 43.57 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 469 / 43.57 |
| Evaporative Heating Surface/Cylinder Volume | 224.40 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 1360 |
| Same as above plus superheater percentage | 1360 |
| Same as above but substitute firebox area for grate area | 6630 |
| Power L1 | 3241 |
| Power MT | 535.89 |