Data from Roy V Wright (Ed.), 1922 Locomotive Cyclopedia of American Practice, Sixth Edition (New York: Simmons-Boardman Publishing Company, 1922), p. 1027. See also Albert H. Smith on the findagrave website at [], last accessed 4 October 2026. Works number was 2618 in March 1917.
This small saddle tank first served the NNY, then moved to the US Naval Gun Factory in the Washington, DC Navy Yard. Connelly's Vulcan production list shows the 5 was bought by the "A H Smith S&G". Locobase is pretty certain this is the company that was founded by Albert H Smith. Findagrave's account give us the following information: "operated at the location of today's Marietta Harbor. It had business property on both the east and west sides of the Muskingum River [in southeastern Ohio] and also operated a river dredge there."
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | 5 |
| Locobase ID | 15001 |
| Railroad | Norfolk Navy Yard |
| Country | USA |
| Whyte | 0-4-2ST |
| Number in Class | 1 |
| Road Numbers | 5 |
| Gauge | Std |
| Number Built | 1 |
| Builder | Vulcan Iron Works |
| Year | 1917 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 7 / 2.13 |
| Engine Wheelbase (ft / m) | 16.50 / 5.03 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.42 |
| Overall Wheelbase (engine & tender) (ft / m) | 16.50 / 5.03 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 113,500 / 51,483 |
| Engine Weight (lbs / kg) | 128,500 / 58,287 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 95 / 47.50 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 50 / 1270 |
| Boiler Pressure (psi / kPa) | 160 / 1100 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 19" x 24" / 483x610 |
| Tractive Effort (lbs / kg) | 23,566 / 10689.37 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.82 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | |
| Firebox Area (sq ft / m2) | 98 / 9.10 |
| Grate Area (sq ft / m2) | 20 / 1.86 |
| Evaporative Heating Surface (sq ft / m2) | 1218 / 113.15 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 1218 / 113.15 |
| Evaporative Heating Surface/Cylinder Volume | 154.57 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 3200 |
| Same as above plus superheater percentage | 3200 |
| Same as above but substitute firebox area for grate area | 15,680 |
| Power L1 | 2890 |
| Power MT | 112.27 |