Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Vol 79, p 147+. Works numbers were 60694-60695 in December 1928.
Little wood-burners described as "switchers" and certainly small enough to discourage very long distance travel on this road. They used Rushton Improved cabbage stacks to catch sparks.
The 4 is described in Gene Connelly's production list as having retired in 1953.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | 3 |
| Locobase ID | 15433 |
| Railroad | Cundinamarca |
| Country | Colombia |
| Whyte | 0-4-2T |
| Number in Class | 2 |
| Road Numbers | 3-4 |
| Gauge | Metre |
| Number Built | 2 |
| Builder | Baldwin |
| Year | 1928 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 4.50 / 1.37 |
| Engine Wheelbase (ft / m) | 11 / 3.35 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.41 |
| Overall Wheelbase (engine & tender) (ft / m) | 11 / 3.35 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 35,200 / 15,966 |
| Engine Weight (lbs / kg) | 40,200 / 18,234 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 500 / 1.89 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 29 / 14.50 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 33 / 838 |
| Boiler Pressure (psi / kPa) | 160 / 1100 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 10" x 16" / 254x406 |
| Tractive Effort (lbs / kg) | 6594 / 2990.99 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.34 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 83 - 1.75" / 44 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 7.67 / 2.34 |
| Firebox Area (sq ft / m2) | 35 / 3.25 |
| Grate Area (sq ft / m2) | 7.06 / 0.66 |
| Evaporative Heating Surface (sq ft / m2) | 323 / 30.01 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 323 / 30.01 |
| Evaporative Heating Surface/Cylinder Volume | 222.08 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 1130 |
| Same as above plus superheater percentage | 1130 |
| Same as above but substitute firebox area for grate area | 5600 |
| Power L1 | 3013 |
| Power MT | 377.42 |